Function: Control Room Output Select
Byte Value Description
1 F0H System-Exclusive Message
2 00H 1st Byte of Studio Tech ID
3 00H 2nd Byte of Studio Tech ID
4 56H 3rd Byte of Studio Tech ID
5 01H Product ID (Model 50)
6 09H Function: Control Room Output Select
7 nnH Output Selected, Range 00-33:
L Ch. R Ch. Action
0 0 No Output
1 0 Left Only, Output A On
2 0 Left Only, Output B On
3 0 Left Only, Outputs A & B On
0 1 Right Only, Output A On
0 2 Right Only, Output B On
0 3 Right Only, Outputs A & B On
1 1 Left and Right, Output A On
2 2 Left and Right, Output B On
3 3 Left and Right, Outputs A & B On
8 F7H EOX, End of System Exclusive
Function: Control Room Mono/Stereo Select
Byte Value Description
1 F0H System-Exclusive Message
2 00H 1st Byte of Studio Tech ID
3 00H 2nd Byte of Studio Tech ID
4 56H 3rd Byte of Studio Tech ID
5 01H Product ID (Model 50)
6 0AH Function: Control Room Mono
7 0nH Output Selected, Range 0-1, 0=stereo, 1=mono
8 F7H EOX, End of System Exclusive
Function: Control Room Dim
Byte Value Description
1 F0H System-Exclusive Message
2 00H 1st Byte of Studio Tech ID
3 00H 2nd Byte of Studio Tech ID
4 56H 3rd Byte of Studio Tech ID
5 01H Product ID (Model 50)
6 0BH Function: Control Room Dim
7 0nH Status, Range 0-1, 0=No Dim, 1=Dim
8 F7H EOX, End of System Exclusive